Do you have any questions?
Ask a consultant

Iron removal filter WATEX CMB13

Manufacturer: WATEX
Product code: CMB13
Combination does not exist
700.00
847.00

WATEX CMB13 is automatic water filter for water treatment that can filtrate iron, manganese, odour, turbidity and arsenic, without the use of any reagents. It is based on the oxidation and filtration method. WATEX CMB consists of filter tank, automatic control valve and filtration media. Due to air pillow in the tank, substances that are in water are oxidized and filtered. Filter need drain and electricity connection. Filter is designed for high flow rate and low pressure loss. Rinsing water can be directly discharged to biological wastewater treatment plant.

WATEX CMB13 is also used as a pre-filter for softener or organic removal filter, especially if the water has a specific smell.

Main advantages:

  •  A simple solution for 5 problems - turbidity, iron (up to 3 mg/l), manganese, odour, arsenic
  • Regeneration does not require reagents - no salt, no potassium permanganate (KMnO4)
  • Effective working even at low pH and high content of organics
  • Easy installation and operation
  • Filter service life is more than 10 years
  • Natural, environmentally friendly filtration process. Do not impair the water quality
  • Automatic purification and regeneration
  • High quality materials, components
  • Apply for private houses, cottages, guesthouses, small apartment houses

 

 

 

Show full description

 Technical parameters of filter

Unit

WATEX CMB13

Flow rate Qnom

m3/h

1.0

Flow rate Qmax

m3/h

5.0

Diameter x height

mm

330 x 1570

Weight (empty)

kg

125

Water – drain connection

inches

1”- 3/4''

Automatic control valve

 

Clack WSCl 1'' (USA)

Tank material

 

Composite material – inline PE

with fiberglass outside coating

Filtration media

 

AquaMandix catalytic filter material,

quartz sand of various fractions

The amount of water for one regeneration

liters

~270

Minimum flow rate for rinsing

m3/h

2.6

 

liters/min

43.0

Electricity consumption

W

10

 

Filter operating restrictions:

Max. oxidized iron (Fe3+) content

15 mg/l

Max. dissolved iron (Fe2+) content

3 mg/l

Max. oxidized manganese (Mn2+) content

1 mg/l

Max. hydrogen sulphide (H2S) content

5 mg/l

pH for iron (Fe2+) removal

6.8-9.0

pH for manganese (Mn2+) removal

8.0-9.0

Organic, humus substances, ammonia, chlorine, hardness salts and other contaminants does not adversely affect the filter performance, but reduces the lifetime.

 

Requirements for normal work of equipment:

  • Connection to drain
  • Electricity connection 220 V, 1 phase
  • Water pressure 2 - 6 bar
  • Room temperature above 0° C
  • Water temperature to 25° C
  • Correct installation

Additional equipment options:

  • Condensate isolation for tank
  • By-pass valve – For easier assembly
  • Repair and maintenance kit – Spanner wrench, injectors (2 pcs.)

Width cm

Height cm

Length cm

Weight kg

40.00

160.00

40.00

115.70

Show full description
Show full description