Multimix resins ECOTAR A

Manufacturer:
Product code: ECOTAR-A
Combination does not exist

Ecotar-A (Ecotar-A BIO) is intended for removing dissolved iron, complex organoiron compounds, manganese, and hardness salts from water. It is recommended for the treatment of water from draw wells and low-depth bore wells. Visual evaluation of the initial water: water has a yellow-brown color and forms residual matter during water precipitation.

Ecotar-A BIO also decontaminates water alongside purification. This media includes specially prepared activated carbon additionally. Such carbon prevents bacterial (iron organisms) growth and foreign odors appearance.

Technical specifications:

Media exchange capacity, mg-ekv/l

600

Working flow rate m/h

10-20

pH range

0-14

Bed height, mm, not less

500

Free volume in column for media expansion at baskwash, %

40

Flow rate at backwash, m/h

6-10

Flow rate at brine cycle, m/h

2-4

Flow rate at rinse, m/h

10-20

Regenerating agent

NaCl

NaCl consumption, g/l resin

100-150

 

Recomennded conditions for resins:

 

Limitations

 

 

Ecotar A

Turbidity, max. ppm

3

Iron*, max. ppm

8

Manganese, max. ppm

2

Hardness, max. mg-ekv/l

10

Permanganate oxidizability, max. Mg O2/l

10

Free chlorine, max. ppm

0.1

Total salinity, max. mg/l

2000

Hydrogen sulfide

absence

 

Main properties of resins

Bulk weight, kg/l

0.84-0.98

Particle size range, mm

0.25-5.0

Moisture content, %

45-70

Package, liters

28.3

 

 